Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520212

ABSTRACT

ABSTRACT Purpose: This study aimed to compare four depths of manual dissection for the preparation of Descemet stripping endothelial keratoplasty lamellae. Methods: Eye bank corneas were randomized into four groups according to dissection depths: Pachy-100 (incision depth = central corneal thickness-safety margin of 100 µm), Pachy-50 (safety margin of 50 µm), Pachy-0 (no safety margin), and Pachy+50 (incision depth = central corneal thickness + 50 µm). All endothelial lamellae were prepared using a standardized method of manual dissection (Pachy-DSEK). The central, paracentral (3.0-mm zone), and peripheral (6.0-mm zone) lamella thicknesses and incision depths were measured by optical coherence tomography. The 3.0-mm and 6.0-mm zone central-to-peripheral thickness ratios were calculated. Results: Endothelial perforation occurred only in the Pachy+50 group (n=3, 30%). Central lamella's thickness in Pachy-100, Pachy-50, Pachy-0, and Pachy+50 groups measured 185 ± 42 µm, 122 ± 29 µm, 114 ± 29 µm, and 58 ± 31 µm, respectively (p<0.001). The overall 3.0- and 6.0-mm C/P ratios were 0.97 ± 0.06 and 0.92 ± 0.14, respectively. Preoperative donor characteristics were not correlated with most thickness outcomes. The planned incision depth correlated significantly with most lamella's thickness parameters (p<0.001). The overall thickness of the lamella negatively correlated with the planned incision depth (p<0.001, r=-0.580). The best outcome was found in the Pachy-0 group, as 75% of the lamellae measured <130 µm and there was no endothelial perforation. Conclusions: By using a standardized method of dissection, most manually prepared lamellae presented a planar shape. Setting the incision depth to the central corneal thickness did not result in endothelial perforation and a high percentage of ultrathin lamellae was achieved.


RESUMO Objetivo: Comparar quatro profundidades de dissecção manual usadas no preparo de lamelas para transplante endotelial. Métodos: Córneas humanas de treinamento disponibilizadas foram randomizadas em quatro grupos: Pachy-100 (profundidade de incisão = espessura corneana central - margem de segurança de 100 µm), Pachy-50 (margem de segurança de 50 µm), Pachy-0 (sem margem de segurança) e Pachy+50 (profundidade de incisão = espessura corneana central + 50 µm). Todas as lamelas foram dissecadas através um método padronizado e já publicado (Pachy-DSEK). As espessuras das lamelas (centro, zona de 3,0mm e zona de 6,0mm) foram medidas com tomografia de coerência óptica. A razão de espessura centro-periferia foi calculada aos 3,0 e 6,0 mm de diâmetro. Resultados: Perfuração endotelial ocorreu apenas no grupo Pachy+50 (n=3, 30%). A espessura central da lamela nos grupos Pachy-100, Pachy-50, Pachy-0 e Pachy+50 foi de 185 ± 42 µm, 122 ± 29 µm, 114 ± 29 µm, e 58 ± 31 µm, respectivamente (p<0,001). As razões C/P aos 3,0 e 6,0 mm foram de 0,97 ± 0,06 e 0,92 ± 0,14, respectivamente. Os parâmetros de características do doador não se correlacionaram com os resultados de espessura de lamela. A profundidade planejada de incisão se correlacionou com a maioria dos parâmetros de espessura de lamela (p<0,001). A espessura de lamela se correlacionou negativamente com a profundidade planejada da incisão (p<0.001, r=-0,580). O melhor resultado foi observado no grupo Pachy-0, em que 75% das lamelas mediram abaixo de 130 µm e não houve perfuração endotelial. Conclusão: Através de um método padronizado de dissecção, a maioria das lamelas endoteliais apresentou uma configuração planar. O planejamento de profundidade de incisão igual à espessura corneana central resultou em alta porcentagem de lamelas ultrafinas sem ocorrência de perfuração.

2.
Arq. bras. oftalmol ; 79(6): 366-368, Nov.-Dec. 2016. graf
Article in English | LILACS | ID: biblio-838754

ABSTRACT

ABSTRACT Purpose: The optical quality of the interface after deep anterior lamellar keratoplasty (DALK) using the big-bubble technique has been shown to be excellent, leading to results comparable to penetrating keratoplasty. However, there is little in the literature with respect to the controversy surrounding the preparation of the donor cornea. The purpose of this study was to evaluate visual acuity (VA) in patients with keratoconus who underwent DALK without removal of the donor graft endothelium. Methods: The records of 90 patients who underwent DALK without the removal of the Descemet membrane (DM) and endothelium were retrospectively reviewed. Data collected included uncorrected VA (UCVA) and spectacle-corrected VA (SCVA) at 7, 30, 180 days, and 1 year postoperatively. Contact lens-corrected visual acuity (CLVA) was evaluated after 1 year of the procedure. Results: UCVA was significantly better than preoperative values at 7 days (p<0.001), 30 days (p<0.001), 180 days (p<0.001), and 1 year (p<0.001) after surgery. The 1-year postoperative mean SCVA and CLVA also improved when compared with preoperative SCVA (p<0.001 for both). Conclusions: DALK utilizing donor corneas with attached Descemet membrane and endothelium results in satisfactory VA in patients with keratoconus.


RESUMO Objetivos: A qualidade óptica da interface após ceratoplastia lamelar anterior profunda (DALK) utilizando a técnica de "Big Bubble" mostrou-se ser excelente, levando a resultados comparáveis aos da ceratoplastia penetrante. No entanto, há poucos dados na literatura com respeito à controvérsia em torno da preparação da córnea doadora. O objetivo deste estudo foi avaliar a acuidade visual (VA) em pacientes com ceratocone submetidos DALK sem a remoção da membrana de descemet e endotélio do tecido doador. Métodos: Os prontuários de 90 pacientes que foram submetidos a DALK sem a remoção da membrana Descemet (DM) e do endotélio foram avaliados retrospectivamente. Os dados coletados incluíram VA sem correção (UCVA) e VA corrigida por óculos (SCVA) aos 7, 30, 180 dias, e 1 ano de pós-operatório. A acuidade visual corrigida por lente de contato (CLVA) foi avaliada após 1 ano do procedimento. Resultados: UCVA no pós-operatório melhorou após 7 dias (p<0,001); 30 dias (p<0,001); 180 dias (p<0,001); e após 1 ano (p<0,001). Ocorreu melhora da SCVA pré-operatória quando comparada com a SCVA e CLVA após 1 ano (p<0,001 para ambos). Conclusão: Transplante lamelar anterior utilizando córneas doadas com membrana de Descemet e endotélio demonstrou resultados visuais satisfatórios em pacientes com ceratocone.


Subject(s)
Humans , Male , Adolescent , Adult , Young Adult , Tissue Donors , Endothelium, Corneal/transplantation , Visual Acuity/physiology , Keratoplasty, Penetrating/methods , Descemet Membrane/surgery , Keratoconus/surgery , Postoperative Period , Time Factors , Retrospective Studies , Treatment Outcome , Preoperative Period , Organ Sparing Treatments/methods , Graft Rejection
SELECTION OF CITATIONS
SEARCH DETAIL